Skip to content
Back to Blog
Sustainability & Energy

Solar and Battery Peak Shaving: A Business Case Guide

July 3, 2026
MAFM Team
7 min read
Solar and Battery Peak Shaving: A Business Case Guide

Solar and battery storage peak shaving uses rooftop generation to cover daytime use and a battery to cover the expensive evening hours and the building's highest spikes. A sound business case for it adds up several separate value streams, uses your own utility bills as the starting point and treats any payback figure as an estimate until a quote and an interval-data analysis back it up.

This post is a planning guide for owners and facility managers in PG&E territory. It does not give payback numbers, because none that apply to every building exist. It shows what to count, which rules to check and who needs to be at the table.

What does peak shaving actually mean?

Peak shaving is cutting the highest points of a building's electric demand. Solar produces during the day, so it offsets daytime use. A battery stores energy and releases it later, which is why the two are often paired: PG&E describes storing solar power during the day and deploying it during peak-cost periods when it will save you the most on your electricity bill.

Peak shaving matters most where a bill has a demand charge, which is based on your highest 15-minute interval in the billing month. PG&E states that if your business faces high demand charges, adding an energy storage system will save you money. Our post on demand charge management explains how that charge works and whether your plan carries one.

Which value streams belong in the business case?

List each stream separately and put a number on it only from your own bills and quotes. The common ones for a PG&E commercial building are:

  • Energy the solar system produces and your building uses instead of buying
  • Credits for energy exported to the grid, which depend on when it is exported
  • Lower demand charges, if your plan has them and the battery covers your peaks
  • Time-of-use savings from using stored energy during the peak window
  • Backup power during an outage, which has a value even if it is hard to price
  • Incentives and tax treatment, which change and need current verification

Counting only the first line understates a system that is designed around the others. Counting all of them without checking your rate plan overstates it, because some streams overlap or do not apply to your account.

How does California net billing change the numbers?

It makes timing matter more than volume. Since April 15, 2023, new solar customers in PG&E, SCE and SDG&E territory have taken service on the net billing tariff, according to the California Public Utilities Commission. Under it, compensation for exported energy reflects the value of that energy to the grid and is usually lower than the retail rate, though the CPUC notes it can rise above retail on late summer evenings.

The CPUC also states that customers can maximize bill savings by installing battery storage with their generation, so they can use or export stored energy during high-value hours, and that nearly 70 percent of net billing customers had paired batteries with solar by the end of 2024.

PG&E's business guide adds the practical details: Solar Billing Plan customers must enroll in a time-of-use plan, and credits are higher for energy sent to the grid during peak hours, 4 p.m. to 9 p.m. Credit values vary by day, month and season, so use the current table, not an old estimate.

What do incentives and tax credits look like now?

They are the least stable part of the case, so verify them the month you decide. Two points are documented as of November 2026.

First, federal tax credits for solar changed in 2025. IRS Notice 2025-42 explains that the clean electricity investment credit terminates for applicable solar facilities placed in service after December 31, 2027, and that the termination applies to facilities whose construction begins after July 4, 2026. Whether and how a given project qualifies, including for storage, is a question for your tax advisor and your installer.

Second, PG&E's Self-Generation Incentive Program offers rebates for battery storage. PG&E's page says non-residential customers may receive up to 25 percent funding under the general market rebate, subject to program budgets, and that non-residential participants must be in one of the listed demand response programs. Check the current page for eligibility and available funding.

What does it do for outages?

A battery can keep selected loads running during an outage, which PG&E lists as a reason to consider one. PG&E notes it must shut power off for safety during periods of high fire risk, that outages can last multiple days, and that how long a battery lasts depends on the system. Your storage provider can assess how long a battery or a battery-and-solar system will last.

The practical step is deciding in advance which loads the battery must carry: life safety, security, communications, perhaps a server closet or refrigeration. Our post on planning for public safety power shutoffs covers that planning.

What should facility managers plan for on the roof?

A solar array changes how roof work is done. OSHA's guidance on solar installations notes that as more panels go on a roof, the walking area may shrink, which can force workers to squeeze by or walk close to skylights, and that maintenance work is generally covered by general industry standards. Workers exposed to fall hazards of 4 feet or more must be protected by a standard railing or a fall protection device.

Before an array goes in, ask where roof access, anchor points and walkways will be afterward, and who will service the HVAC units that share the roof. Contractors who clean, inspect or repair anything on that roof need to know the layout.

Who should be at the table?

At minimum: the owner or finance lead, a solar and storage installer who will quote against your interval data, an electrician or engineer, and the facility manager who will live with the system. Ask every installer for the assumptions behind their numbers, including the rate plan, the export credit values and the incentive status, and compare quotes on the same assumptions.

MAFM does not design, install or finance solar or storage. What a facility management partner does is keep the building's records, schedules and vendors in order so the project fits the building: access plans, shutdown coordination during installation and maintenance schedules afterward.

Frequently asked questions

Does solar alone reduce demand charges?

Not reliably. Demand is set by your highest 15-minute interval, and a cloudy afternoon or an evening peak can fall outside solar production. A battery is what targets those peaks, which is why PG&E links storage with high demand charges.

Is net metering still available for new commercial solar?

Generally not for new applications. The CPUC says that since April 15, 2023, customers applying for interconnection have taken service on the net billing tariff. Ask your installer which tariff your project would fall under.

What payback should I expect?

It depends entirely on your rate plan, your interval data, system cost, incentives and tax treatment, so any general figure is a guess. Ask installers for a written analysis using your bills and compare them on the same assumptions.

Can the building's facility team maintain a solar and battery system?

Routine building tasks, yes, but the equipment itself is serviced by qualified solar and electrical contractors under manufacturer guidance. A facility manager coordinates access, scheduling and records.

Next step

If you are weighing solar or storage, start by gathering a year of bills and interval data and a map of roof access. Talk to MAFM about facility management for your building, or see our San Jose page. For a broader look at the technology, read our post on commercial solar and battery storage in Silicon Valley.

Ready to Optimize Your Facilities?

MAFM offers comprehensive facility management solutions tailored to your business needs.

Get in Touch