Office Indoor Air Quality: A Facility Manager's Guide

February 17, 2026
MAFM Facilities Management Team
9 min read
Office Indoor Air Quality: A Facility Manager's Guide

Office indoor air quality depends on four things a facility team can control: how much outdoor air the HVAC system delivers, how well that air is filtered, how much pollution is released inside, and how well moisture is managed. None of them is visible, which is why they slip down the list until a tenant complains.

The case for paying attention is straightforward. EPA says Americans spend about 90 percent of their time indoors, where the concentrations of some pollutants are often 2 to 5 times higher than outdoors. OSHA's technical manual says inadequate or improper ventilation causes about half of all indoor air quality problems in nonindustrial workplaces. Both point to the same place: the building's systems and how they are maintained.

Does indoor air quality really affect how people work?

Probably yes, but the research is thinner than the headlines suggest. Two controlled studies are the ones most often cited, and both are small.

In a 2016 study of 24 participants who spent six full workdays in a controlled office, Allen and colleagues found cognitive scores about 61 percent higher on a low-VOC "green" day and about 101 percent higher on days that also had extra outdoor air, with VOCs and carbon dioxide each independently associated with scores. A 2012 study of 22 mostly student participants tested CO2 at about 600, 1,000 and 2,500 ppm in 2.5-hour sessions. Decision-making scores fell moderately at 1,000 ppm and sharply at 2,500 ppm, though the authors said confirmation was needed.

ASHRAE is more cautious. Its February 2025 position document says that evidence for direct effects of CO2 on work performance at commonly observed indoor concentrations is inconsistent and does not currently justify changes to ventilation standards. It also says indoor CO2 is not an overall indicator of air quality, though it can be a useful tool when its limits are understood.

The practical reading for a facility manager is this. CO2 trending high in a room is a reason to check ventilation, not proof of lost productivity. If you add sensors, location and calibration matter, because the same ASHRAE document warns that sensor performance, placement and calibration decide whether the readings mean anything.

What does California require of an office building's ventilation?

California puts ventilation upkeep on the employer, with records. Cal/OSHA Title 8 section 5142 requires HVAC systems to be maintained and operated to provide at least the outdoor air quantity required by the building standards in effect when the building permit was issued, and to run continuously during working hours except for scheduled maintenance, emergency repairs, limited utility demand reductions and similar listed cases.

The same section requires the system to be inspected at least annually, with problems corrected within a reasonable time. The inspection and maintenance record has to name who did the work, the date, what was found and what was done, and be kept for at least five years.

That makes a documented annual HVAC inspection more than good practice. It also tells you what to ask your HVAC contractor for: a written report you can file, not a verbal "all good."

What should a building check on the HVAC side?

Start with the parts that decide how much clean air actually reaches people. These are the items a facility team can verify on a schedule:

  • Outdoor air intake: confirm the dampers open and close, the actuators respond and the intake is not blocked or pulling from a loading dock or exhaust discharge. OSHA notes that outside air for ventilation may bring contaminants into the workplace, with vehicle emissions as an example.
  • Filters: correct size, seated properly, no bypass around the frame, changed on the manufacturer's schedule.
  • Operating schedule: ventilation running whenever the building is occupied, including early starts and late meetings.
  • Exhaust: restroom, break room and copy room exhaust fans actually moving air, not just humming.
  • Dense rooms: conference rooms and open areas with many people per square foot are where ventilation shortfalls show first.

Most of these are not janitorial tasks, and MAFM does not repair HVAC equipment. What a facility partner does is put them on a calendar, track the contractor's findings and make sure a failed damper or a loose filter gets a work order instead of a shrug.

How should you choose HVAC filters and portable air cleaners?

Pick the highest filter rating your equipment can handle, not the highest rating available. EPA describes MERV as a filter's ability to capture particles between 0.3 and 10 microns, on a scale from 1 to 16, and advises consulting an HVAC technician about the best filter for a particular system. Denser filters resist airflow, so the fan and filter slot set the limit.

For commercial buildings, the ASHRAE planning framework that EPA points to recommends evaluating whether the HVAC system can handle MERV 13 or higher filters. That evaluation, plus a full maintenance check, is best done before smoke season rather than during it. For more on grades, see our post on choosing a MERV rating.

Portable air cleaners are a supplement for problem rooms. EPA explains that they are rated by clean air delivery rate (CADR), and that filtration does not replace the need to control pollutants and ventilate. Size the unit to the room using the manufacturer's coverage rating, and budget for filter replacement, because a spent filter does nothing.

How do you handle wildfire smoke in an office building?

Write a smoke plan before the smoke arrives. The ASHRAE planning framework, summarized in an EPA flyer for commercial buildings, lists ten elements. The ones a facility team can start on now:

  • Buy supplies in advance, including portable air cleaners and extra filters
  • Check whether the HVAC system can take MERV 13 or higher filters
  • Run a full HVAC maintenance check and make repairs
  • Add a port or pressure gauge to read filter pressure drop on at least one air-handling unit
  • Weatherize the building and limit which entrances are used
  • Buy low-cost PM2.5 sensors to watch indoor trends
  • Identify a space that can serve as a temporary cleaner-air room
  • Reduce indoor particle sources such as cooking, vacuuming and printing during an event

For employers there is a legal trigger as well. Cal/OSHA's wildfire smoke standard, section 5141.1, applies when the current AQI for PM2.5 is 151 or greater and employees may be exposed. It exempts enclosed buildings where a mechanical ventilation system filters the air and windows, doors and other openings are kept closed. AirNow's scale puts 151 to 200 in the "Unhealthy" category. Keeping the ventilation system maintained and the doors shut is what keeps that exemption available.

Our post on wildfire smoke and building operations goes deeper on operating procedures.

Where do VOCs and humidity come in?

Both are mostly source and moisture control, which is cheaper than treating them later. EPA says concentrations of many VOCs are consistently higher indoors than outdoors, by up to ten times, and lists paints, cleansers, aerosol sprays, air fresheners, building materials, furnishings and office equipment among the sources. Short-term effects include eye, nose and throat irritation. EPA's advice is to remove the source where possible and increase ventilation while using products that emit VOCs.

In an office that translates into simple habits:

  • Schedule painting, carpet installation and furniture delivery for times when the ventilation can run and the space is empty, and allow the air to clear before people return
  • Choose cleaning chemicals deliberately and skip scented air fresheners
  • Keep printers and copiers in open, ventilated areas

On humidity, EPA recommends keeping indoor relative humidity below 60 percent, ideally between 30 and 50 percent, and OSHA lists 60 percent or less as a microbial control measure. Fix leaks and wet materials promptly, since moisture is what lets mold start.

What does an indoor air quality walkthrough look like?

A quarterly walkthrough turns all of the above into a punch list. A cleaning crew sees every room every day, so they are well placed to spot problems that never reach a work order. A reasonable list:

  • Dust on supply diffusers and return grilles, which can signal poor filtration or low airflow
  • Restroom and break room exhaust fans that are not pulling air
  • Stained ceiling tiles, musty smells or visible condensation
  • Stuffy conference rooms after long meetings
  • Filter condition and the date of the last change
  • Blocked vents and furniture pushed against returns
  • Entry mats worn through or missing, so grit and dust walk in on shoes
  • The most recent annual HVAC inspection report, filed and dated

Photograph what you find, date the list and feed the open items to your HVAC and building engineering vendors.

Frequently asked questions

What is a healthy CO2 level in an office? There is no single legal or ASHRAE limit for indoor CO2. ASHRAE's position is that indoor CO2 is not an overall indicator of air quality, but readings that run well above outdoor levels in an occupied room are a reason to check ventilation.

How often should office HVAC filters be changed? Follow the manufacturer's schedule and inspect between changes, because EPA advises following manufacturer recommendations for maintenance and replacement. Filters that are visibly loaded, damaged or bypassed need changing sooner, and smoke events load them faster.

Does California require annual HVAC inspections? For employers, yes. Title 8 section 5142 requires at least annual inspection of mechanical HVAC systems and written records kept for at least five years.

Do air purifiers replace good ventilation? No. EPA states that filtration does not replace the need to control pollutants and ventilate. Portable units help in specific rooms during smoke or near heavy sources.

Put air quality on the facility calendar

Air quality holds up when someone owns the schedule: inspections, filter changes, smoke prep and a regular walkthrough. MAFM's facility management team plans that calendar, coordinates your HVAC and building engineering vendors and tracks open items to completion. See how that works for San Jose buildings, or talk to us about facility management.