A facility management budget template for a tech campus is a list of cost categories, each built from a quantity, a frequency and a unit price taken from real quotes, plus reserves for the things that will break. It is not a table of per-square-foot allocations copied from someone else's building, which is what most online templates are.

This post gives the categories a tech campus needs, the inputs to collect for each, and the public benchmarks that are worth using as sanity checks. It leaves out dollar amounts per square foot on purpose: nobody can set yours without your scope, your quotes and your utility bills.

What categories belong in a tech campus facility budget?

Start with ten lines. Tech campuses differ from a standard office mainly in the amenity and event load, long operating hours and specialty rooms, so those get their own lines instead of hiding in "other."

  • Janitorial and day porter: nightly cleaning, restrooms, kitchens and breakrooms, plus daytime coverage for spills, restocking and meeting-room turnover.
  • Specialty cleaning: carpet extraction, hard-floor restoration, interior glass, high dusting and post-construction cleaning after tenant improvements.
  • Building systems maintenance: HVAC, plumbing, electrical, elevators, fire and life safety, and the building automation system, each under its own service contract.
  • Grounds and exterior: landscaping, irrigation, parking areas, walkways and exterior lighting.
  • Supplies and consumables: paper, soap, liners, chemicals and kitchen supplies.
  • Utilities: electricity, gas, water, sewer and waste, tracked per meter.
  • Workplace and amenity services: event setup, wellness rooms, game rooms, pantry and café support.
  • Technology: work order software, sensors, and any license or integration cost.
  • Capital reserve: planned replacement of roofs, chillers, flooring and other long-life items. Keep it separate from operating spend.
  • Contingency: an explicit line for the failure nobody scheduled, so that it does not raid the other nine.

MAFM does not perform every one of these trades. Licensed trades such as HVAC, electrical and elevators stay with licensed contractors. What a facility management partner adds is the scheduling, vendor coordination and records that make each line item predictable.

How do you build each line item?

Use the same three inputs for every line: a driver, a frequency and a unit price. Then write down where each number came from.

A working line has these fields, in this order:

  • Driver: the thing that creates the work, such as restroom count, floors, rooftop units or occupied square feet.
  • Quantity and frequency: how many, and how often, in writing. "Weekly" can be priced. "As needed" cannot.
  • Unit price and its source: a signed quote, a contract rate or an invoice, with the date.
  • Annual cost: the product of the three.
  • Owner and contract end date: who answers for the line, and when the price can next be renegotiated.

Collect at least two quotes against the same written scope. If two vendors price different scopes, the comparison tells you nothing.

Which benchmarks are public and trustworthy?

Few, and each has limits. Use them to check your numbers, not to replace them.

  • Routine maintenance and repair against replacement value: the National Research Council's guideline, restated in a 2001 report on federal facilities, is that routine maintenance and repair for "a substantial inventory of facilities" typically runs 2 to 4 percent of the aggregate current replacement value, and the same report says there is no single agreed guideline (National Research Council, Deferred Maintenance Reporting for Federal Facilities, 2001). It is a rough check for a portfolio, not a rule for one building.
  • Maintenance approach: the U.S. Department of Energy's O&M guide says preventive maintenance can save as much as 12% to 18% over a purely reactive program (DOE FEMP O&M Best Practices Guide, 2010).
  • Energy: the U.S. Energy Information Administration reported that commercial buildings spent $142 billion on energy in 2018, averaging $1.47 per square foot (EIA, September 2022 release). That is all commercial building types, not tech campuses, and it predates recent rate changes.

Be wary of any template that lists a per-square-foot range for janitorial, HVAC or grounds without a source. Industry reports such as BOMA's Experience Exchange Report compare operating costs by market and building type, but check the year and the building type before relying on any figure.

How do labor costs flow into the budget?

Directly. Janitorial, day porter and light maintenance are labor-priced, so the wage environment sets the baseline.

San Jose's minimum wage is $18.45 an hour for 2026 (CalChamber). The Bureau of Labor Statistics put the mean wage for janitors and cleaners in the San Jose-Sunnyvale-Santa Clara area at $22.55 an hour in May 2025, against $18.64 nationally.

A vendor's price also has to cover more than the wage. Across private industry, benefits made up 30.0 percent of employer compensation costs in June 2026 (BLS, Employer Costs for Employee Compensation). Ask each bidder to show its labor rate, burden, supervision and margin as separate lines. A bid that cannot be broken down cannot be compared, and a bid far below local wage levels is a warning.

Shift differentials for evening, overnight or weekend work should appear as their own line too. Do not assume a percentage; ask the vendor to state it.

How should you budget energy and utilities?

From your own bills first, then adjust for change. Pull twelve months of statements for every meter, note the rate schedule, and separate fixed charges from usage.

Two public reference points help. ENERGY STAR says certified buildings use, on average, 35 percent less energy than similar buildings nationwide, which tells you the gap between average and well-run buildings can be large. The EIA's 2018 survey shows offices accounted for 19% of major fuels expenditures among commercial buildings, so offices are a major cost center in the category.

If your campus has any building over 50,000 square feet, California requires annual energy reporting through ENERGY STAR Portfolio Manager by June 1 (California Energy Commission, Building Energy Benchmarking Program). That data doubles as your utility baseline.

How do you plan maintenance, capital and contingency?

Separate three kinds of money, because they behave differently.

  • Scheduled maintenance: filters, inspections, service visits and routine repairs, from a written calendar. For commercial HVAC, ASHRAE Standard 180 lays out the inspection and maintenance tasks needed to keep comfort, efficiency and air quality acceptable.
  • Capital reserve: the replacement of long-life assets. Build it from an asset list with age, expected life and replacement estimate, not from a percentage of the operating budget.
  • Contingency: a fixed amount you agree on in advance for unplanned repairs. Review how much of it was used each year and resize it from that history.

Track emergency calls against scheduled visits. If the contingency line keeps running out, the maintenance calendar is not doing its job.

How do you track the budget month to month?

Monthly for variance, quarterly for decisions. Break the annual budget into months using your own history, since seasonal swings differ by building: rain season, cooling season, holiday closures and tenant-improvement work all move spending.

A quarterly review that stays short:

  • Actual versus budget by category, with the reason for every variance above a threshold you set in advance
  • Vendor performance against the scorecard, because a late or missed visit is a cost too
  • Reforecast of the remaining quarters from actuals, not from the original plan
  • Capital items that moved forward or back
  • Contracts reaching renewal in the next two quarters

Our guide to a facility assessment template shows how to build the asset and condition data these lines depend on.

Frequently asked questions

What percentage of a facility budget should go to maintenance?

There is no sound universal percentage of the budget. The commonly cited benchmark is a share of replacement value rather than of spending: the National Research Council guideline of 2 to 4 percent for routine maintenance and repair of a large inventory of facilities. Use it as a cross-check on your own line items.

What should we budget per square foot for janitorial service?

Get written quotes on a written scope and divide by square feet afterward. Local wages drive the price, and San Jose's 2026 minimum wage alone is $18.45 an hour. A per-foot figure from another market or year will mislead you.

Should the capital reserve sit inside the operating budget?

Track it separately, even if it is funded from the same source. Mixing the two hides the real cost of running the building and makes a deferred replacement look like a saving.

How often should we revise the budget?

Review monthly, reforecast quarterly and rebuild annually. Rebuild earlier if a major contract, wage rule or occupancy pattern changes.

Build your budget with MAFM

MAFM is a facilities management company in San Jose. We can help you write the scope for each line, coordinate your specialty vendors and keep the records the budget depends on. See our facility management services, or read our companion post on how to reduce facility operating costs. For the local picture, see MAFM in San Jose.